Authors: Ehsani S, Siadat H, Alikhasi M.
Implant Dent, Vol.23, No.2, 2014,Page

Abstract

PURPOSE

The aim of this in vitro study was to compare the accuracy of implant impressions in parallel and nonparallel implants of All-on-Four treatment plan.

MATERIALS AND METHODS

A reference model containing 4 internal-connection implant analogs was fabricated according to All-on-Four treatment plan (2 anterior implants at 0 degree and 2 posterior implants at 30 degrees in relation to the perpendicular line). Twenty impressions of this model were made using open-tray impression technique. Impressions were poured with American Dental Association type 4 stone, and the positional accuracy of the implant replica heads in x-, y-, and z- axes was evaluated using a coordinate measuring machine. These measurements were compared with the obtained measurements from the reference model that served as control, and data were analyzed using independent test (α = 0.05).

RESULTS

The results showed that the accuracy of the implant impressions did not show any significant difference between the tilted and straight implants except in y-coordinate (P = 0.012).

CONCLUSION

Within the limitations of this study, the accuracy of the implant impressions did not differ for different implant angulations in All-on-Four treatment plan.